1 Secvest 2Way O P E R A T I N G I N S T R U C T I O N S BOM-No 12000869

Pagina 2 - Introduction

10 8.3. Delay time started The alarm system starts the delay time, but with a pulsed tone instead of a continuous tone. This indicates that one or

Pagina 3 - 2. Contents

119. Following successful activation When the alarm centre is successfully activated (also with automatically omitted zones), an acknowledgement is

Pagina 4 - !IMPORTANT!

1210. Deactivating the wireless alarm system The wireless alarm system can be deactivated in a variety of ways: • Deactivation of the entire system

Pagina 5

1311. Activating partitions If the alarm system is set up so that two or more partitions can be monitored independently of each other, these partiti

Pagina 6 - 01/05/2008

14 12. Internal activation In addition to monitoring one or more partitions (i.e. objects or company departments) separately, the system also has an

Pagina 7 - 6.5. Wireless cylinder

1513. Alarms The wireless alarm system has three different types of alarm. Depending on the system state (deactivated, internally activated, activa

Pagina 8 - 8. Unsuccessful activation

1614. Resetting the alarm If the alarm system has triggered an alarm (whether local, external or silent), then this must first be acknowledged and

Pagina 9 - (omitted) zones

1715. Alarm transmission by telephone In addition to alarms from sirens and signalling devices, the wireless alarm system can also transmit an alar

Pagina 10 - 8.3. Delay time started

18The alarm centre registers the status of your commands through different tones: Beep = Command accepted Beep, beep = Action carried out Bup = A

Pagina 11

1918. Settings in the user menu 18.1. First steps in the user menu In the user mode, proceed as follows: Press the control button under Menu. E

Pagina 12 - 10.4. Wireless cylinder

2 Preface Dear customers, Many thanks for your purchase of the SECVEST 2Way wireless alarm centre. This device is built according to state-of-the-

Pagina 13 - 11. Activating partitions

2018.3. Recording voice messages The wireless alarm centre enables the user to record individual voice messages. These voice messages can be listen

Pagina 14 - 12. Internal activation

2118.4. Omitting zones If necessary, you can remove zones from surveillance (e.g. if a detector is defective or a zone cannot be closed).

Pagina 15 - 13. Alarms

2218.5.1. Editing users After selecting the Edit User menu item, the user attributes can be edited. Select the user whose attributes

Pagina 16 - 14. Resetting the alarm

2318.5.1.2. Changing the user type Select the user type: • Normal User • Administrator In contrast to the normal user, the administra

Pagina 17

2418.5.1.4. Changing the user code Select the Code menu item. Enter the new four-digit code via the keypad. After entering the last digi

Pagina 18 - 17. User menu

25Training the chip key Select Tag. The system prompts you to hold the chip key over the system reader. Hold the chip key over the alarm s

Pagina 19

2615.5.2. Adding users To add a new user to the wireless alarm system, select the Add User menu item. You are now guided through the rema

Pagina 20

2718.6. Viewing the log This function enables you to read the event log. This log contains the last 250 events together with the date and time. The

Pagina 21 - 18.5. Installing users

28System Rearmed The system has automatically reactivated itself following an alarm. U-- Z== Omit User -- has omitted zone ==. Fire Z== Alarm Zon

Pagina 22

29 18.7. Additional functions In this menu, a user can switch the functions assigned to them by the installer on and off. Select the Faci

Pagina 23

3 2. Contents Preface ... 2 Introduction ..

Pagina 24

3018.8. Test This menu is used to test the different alarm centre functions. Select the “Test” menu item. Select the function

Pagina 25

31Outputs A list of all outputs installed on the system is shown on the display. Select the output to be tested. Press Done to end the test. IMPORT

Pagina 26

32 Function Meaning Set Date & Time Select this point to enter the date and time of the wireless alarm system. Edit Outputs Select this poi

Pagina 27 - 18.6. Viewing the log

3318.9.1. Week Planner Only users with administration rights can install this function. The system should be activated and deactivated according t

Pagina 28

3418.9.2. Activation / deactivation of the week planner Access the user menu using the administrator code (default = 1234) and create a week planne

Pagina 29 - 18.7. Additional functions

3518.9.4. Auto Set Select the time for Auto Set (00:00). Æ Select data record 1. Æ Select activated

Pagina 30 - 18.8. Test

3618.9.5. Auto Unset Select the time for the Auto Unset (07:20). A data record has now been programmed for Mon

Pagina 31 - 18.9. System configuration

37 18.9.6. Internal and external activation In this example, partition 1 is switched from internal activation (external perimeter protection) to ex

Pagina 32

3818.9.6. Activating and deactivating data records To deactivate a data record (time period), make changes in the AUTO SET menu. In AUTO UNSET, cha

Pagina 33 - 18.9.1. Week Planner

3918.10. Follow Me This menu is used for entering the follow me number. This number is dialled to send a voice message to a telephone of your choic

Pagina 34

4 3. Safety information !WARNING! To avoid fire and injury, please note the following: • Securely fasten the device in a dry location

Pagina 35 - 18.9.4. Auto Set

4018.12. Telephone Call This menu is used to start a telephone call manually and test the telephone line or GSM connection. The system uses the int

Pagina 36 - 18.9.5. Auto Unset

4119.1. Errors, meanings, causes and suggested solutions Displayed error Meaning Possible causes Suggested solutions AC Fail The 230 V AC syste

Pagina 37

42Displayed error Meaning Possible causes Suggested solutions Low Batt Z__ No battery power supply in zone __. • The battery capacity in the de

Pagina 38

43 20. Declaration of conformity The declaration of conformity to the applicable guidelines has been made available and signed by Security Center m

Pagina 40 - 19. Error displays

A1 - I Amendments to the operating manual (UK) Secvest 2WAY FU8006 S/W ≥ 5.04.22

Pagina 41

A1 - II 1. Preface Dear customers, We constantly develop our product range in order to provide our customers with optimal products incorporating s

Pagina 42

A1 - III 3. New menu items in user menu 3.1. Secvest Key 2WAY wireless cylinder, item no. FU59xx • Testing User Menu Æ Testing Æ Secvest Key S

Pagina 43 - 21. User menu overview

A1 - IV 3.2. FU8100 wireless remote control User Menu Æ System Config Æ Telecommands Æ 2 Way Instant Set Æ 2 Way Instant Set Y 2 Way Instant Set

Pagina 44

5 4. System and keypad overview 1 – Chip key reader 2 – Graphic display Multiple-line display 3 – Integrated siren 4 – A

Pagina 45 - A1 - I

6 5. Graphic display The graphic display informs you about all events concerning the wireless alarm system. The following is an overview of the diff

Pagina 46 - Æ “About Panel” menu item

7 6. Activating the wireless alarm system The wireless alarm system can be activated in a variety of ways. The system emits an acoustic message. De

Pagina 47 - Æ Testing Æ Secvest Key

8 7. During the delay time Provided no errors that prevent activation have occurred (zone open), the wireless alarm system starts the configured exi

Pagina 48 - A1 - IV

9 Using the control button, select the item under View to display the error. The following graphic display is shown: The wireless alarm s

Commenti su questo manuale

Nessun commento