Abus FU8380 Istruzioni per gli Interventi Pagina 20

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 75
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 19
20
Jumper A
Sensitivity:
The detector can be set to high
or low sensitivity using jumper A.
The sensitivity can be fine-tuned
in the corresponding setting
range using the potentiometer
(see below).
Jumper B
Multiple-vibration mode:
When the multiple-vibration mode
is activated, the vibration detector
only sends an alarm after
repeated vibrations.
Off
On
Jumper C
Calibration:
Use this jumper to set the
detector to calibration mode or
normal operation.
Calibrate detector
Normal
Jumper D
LED:
Use this jumper to deactivate/
activate the LED on the detector.
Off
Low
High
Vedere la pagina 19